Service difficulty report · Filter · Airbus A310324

Difficulty date
September 30, 2010
Submitted
October 15, 2010
Operation
Air carrier
Aircraft
N811FD
Make and model
Airbus A310324
Aircraft serial
457
Aircraft time
44,726 hours, 12,675 cycles
Engine
Pwa PW4152
Part
Filter
Part number
952800AA000PC0A
Part serial
002
Condition
Leaking
Location
Hyd System
Stage of operation
DE
How discovered
O
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING DESCENT RECEIVED ECAM GREEN HYD SYS LOW LEVEL WARNING. HYD QTY ON OVERHEAD PANEL INDICATED ZERO. CONSULTED THE QRH AND MANUALLY EXTENDED THE LANDING GEAR. FOUND HYD LEAKAGE CAME FROM THE GREEN SERVO CONTRO FILTER. REMOVED AND REPLACED THE PUMP DELIVERY FILTER ASSY, REMOVED AND REPLACED THE NR 1 AND 2 GREEN ENGINE PUMP AS PER AMM 29-11-32-04.