As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT INBD MID FLAP INBD ACTUATING MECHANISM PUSH ROD CUTOUT CRACK. CUT OUT DAMAGED AREA OF R/H INBD MIDFLAP T/E CHORD 47 1/2" LONG IAW FED EX B727 SRM REV 103 51-10-1 FABRICATED REPAIR FROM BAC1503-100046 7075 T6 DIM 47 1/2" LONG AND SPLICE FROM BAC1503-100046 7075 T6 DIM 9" LONG IAW B727 SRM 57-50-2 INSTALLED T/E CHORD SECTION AND SPLICE IAW SRM 51-30-2