What was found
06 EACH FASTENER HOLES FOUND CRACK INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS= 683.4 TO STATION XORS= 713.6. REPAIR CARRIED OUT AT LEFT HAND WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS= 683.4 AND STATION XORS=713.6 AS PER BOEING DRAWING SG11570004 REVISION A. THIS REPAIR IS CLASSIFIED AS MINOR AS PER FEDEX GMM 6-2-100 REVISION 111.