What was found
AFT PIT BS 1173 STRINGER AT 22L IS CORRODED. REMOVED DAMAGED STRINGER SECTION DIM. 25 3/8" IAW B727 SRM 53-10-3 AND 51-30-2. FABRICATED NEW STRINGER SECTION FROM BAC1498-144 7075T6 DIM. 25 3/8" AND SPLICE FROM BAC1498-132 7075T6 DIM. 14 3/4" IAW SRM 53-10-2 AND 53-10-3 FIG 1 DETAIL I. INSTALLED NEW STRINGER SECTION AND SPLICE IAW SRM 51-30-2 AND 53-10-3 AT AFT PIT BS 1157 TO 1183.