What was found
MAIN DECK SEAT TRACK GOUGE IN SEVERAL AREAS FROM STA 1540 TO 1640, LBL 45.5. REMOVED GOUGE AREA IAW SRM 51-10-02, ORG MAT THINESS .180" AFTER REWORKED FOUND TO BE OUT OF LIMIT IAW SRM 53-00-52, FIG 101, SH2 PAGE 102 L=6" W=1" D=0.050" R & R SEAT TRACK FROM STA 1540,1640,LBL 45.5 FABRICATED FROM MAT P/N BAC 1520-792 STRUSION BATCH NR1891618 IAW SRM 53-60-52, FIG 1, PAGE 2 AND SRM 51-40-02. MAJOR REPAIR.