What was found
POTENTIAL SHORT EDGE MARGIN CONDITIONS IN 657N3161-12 FITTING DUE TO INCOMING FASTENER HOLE LOCATIONS AT STA 1640, S-17R- 18R. A REPAIR WAS ACCOMPLISHED ON STAM EA 757-5362-16-F2803, FOR POTENTIAL SHORT EDGE MARGIN CONDITIONS IN THE 657N3161-12 FITTING AT STA 1640, STRINGERS 17 AND 18R. 8110-3 , DATED 10/11/2010 ISSUED FOR DTA EVALUATION. EA F-5310-141218 ISSUED TO ESTABLISH DTA TRACKING IN THE SYS. MAJOR ALTERATION.