MAIN DECK - WHILE CARRYING OUT EO 1-2620-7-5005C PT1, 3 EACH EXTRA HOLES DRILLED ON FRAME AT STA 1964 BETWEEN LONGERON 2L TO LONGERON 3L. 03 EACH EXTRA HOLES DRILLED AT MAIN DECK WHILE CARRYING OUT EO 1-2620-7-5005 C PT1 AT STA 1964 BETWEEN LONGERON 2L TO 3L REPAIRED IAW SRM 53-00-07, FIG 201, REV 44. CLASSFIED AS MAJOR REPAIR IAW GMM 6-2-100, REV 111.