What was found
FLOORBEAM CORRODED STA 560, LBL 25 TO LBL 45. CUT-OUT DAMAGED AREA TOP TEE CAP FLOORBEAM BS 560 LBL 36.40 TO 39 APPROX DIM. 2.6" X .90", FABRICATED REPAIR PARTS 2EA ANGLES FROM BAC 1490-2888-7075T6 DIM.19.5" X 0.90" AND 9.6" X .080". REPAIR FILLER FROM 2024T3 0.125" DIM. 2.5" X 0.85" AND INSTALLED REPAIR PARTS IAW SRM 53-10-8 FIG 8, 51-10-2, AND 51-30-2 REV 103.