What was found
WHEN GUARD COVER ON EMERGENCY LIGHTS IS CLOSED IT TURNS THE EMERGENCY LIGHTS TO OFF. FOUND SPRING IN GUARD COVER OF EMERGENCY LIGHT SWITCH LOOSE. ADJUSTED & REINSTALLED SPRING IAW SMP PERFORMED OPS TEST FOR EMERGENCY LIGHT WITH CONTROL SWITCH IAW AMM 33-51-00-5-0 WORKS NORMAL. ACFT OK FOR SERVICE.