What was found
FRAME UPPER FLANGE PUNCTURED - BS 1110 ABOVE STR 27R, BENEATH CARGO NET STANCHION FITTING. CUT OUT DAMAGED AREA DIM 3 7/8" X 1 3/4" IAW SRM 51-40-3 FIG 1. FABRICATED REPAIR USING 7075-0, .063", DIM. 14" X 5 3/4", LOCATED AND DRILLED PART IAW SRM 51-40-3 FIG 1, 53-10-2 FIG 5, AND 51-30-5. TREATED AND PRIMED IAW SRM 51-10-2, INSTALLED REPAIR IAW SRM 51-30-2, REV 103.