What was found
CORROSION TOP "T" CAP FLOORBEAM STA 440, BL 0 - LBL 25, MAIN CABIN CUTOUT DAMAGE AREA AT FLOORBEAM BS 440, LBL 10 IAW SRM 53-10-8 FIG 8, FABRICATED (2) ANGLES REPAIR IAW SRM 53-10-8 FIG 8, & INSTALLED NEW ANGLES REPAIR AT LBL 5 - LBL 13 BS 440 IAW SRM 53-10-8 FIG 8 & SRM 51-30-2