What was found
CORROSION - FRAME SHEAR TIE FORWARD FLANGE, STATION 1148, STRINGER 27L TO STRINGER 26L. REMOVED CORROSION FROM SHEAR TIE WITH A MATERIAL LOSS OF .004, FOUND TO BE WITHIN LIMITS IAW SRM 53-10-1. TREATED AND PRIMED AREA IAW SRM 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION - FRAME SHEAR TIE FORWARD FLANGE, STATION 1148, STRINGER 27L TO STRINGER 26L. REMOVED CORROSION FROM SHEAR TIE WITH A MATERIAL LOSS OF .004, FOUND TO BE WITHIN LIMITS IAW SRM 53-10-1. TREATED AND PRIMED AREA IAW SRM 51-10-2.