As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
VERTICAL STAB INTERIOR AT BS 1343 HAS CRACK INDICATION ON RT UPPER WEB SUPPORT ANGLE, UNDERNEATH. REMOVED CRACKED SHEAR TIE. FABRICATED NEW SHEAR TIE USING 2024T-3 .050 DIMS 7 1/8" X 3 3/4" AND INSTALLED IAW SRM 51-20-1, SRM 55-30-2 AND SRM 51-30-2.