What was found
2EA PLACES OF CORROSION FOUND ON AFT CROSSBEAM IN REAR FUSELAGE FRAME 85, 5" INCHES INBD OF STRINGER 13R (2" SQUARE INCHES). R & R CROSSBEAM AT FRAME 85, STRINGER 13R IAW SRM 51-40- 21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2EA PLACES OF CORROSION FOUND ON AFT CROSSBEAM IN REAR FUSELAGE FRAME 85, 5" INCHES INBD OF STRINGER 13R (2" SQUARE INCHES). R & R CROSSBEAM AT FRAME 85, STRINGER 13R IAW SRM 51-40- 21.