What was found
RT FUSELAGE EXTERNAL SKIN DENT BS 520 BETWEEN STRINGER 24R-25R. FABRICATED, INSTALLED DOUBLER & FILLER 2024-T3 BATCH 0001928869 .063 &2024-T3 .056 BATCH 0001383027 IAW SRM 53-00-01 REPAIR 2 THRESHOLD INSPECTION OF REPAIR DOULBER TO OCCUR ON OR BEFORE 37,500 FLIGHT CYCLES AND INTERVALS OF 6.000 FOR HFEC OR 3,000 FLIGHT CYCLES FOR LFEC THEREAFTER IAW SRM 53-00-01. MAJOR REPAIR.