What was found
MAIN CARGO DECK FRAME AT STA 1100, STRINGER S-2R HAS EXISTING TV MONITOR MOUNT HOLES THAT DOES NOT HAVE PROPER EDS. R & R STRINGER CLIP S2R IAW SRM 51-40-02. CUT OUT FRAME FROM STR 2R TO STR 5R, IAW SRM 53-00-07 FOR SPECIAL FREIGHTER AND REPAIRED IAW SRM 53-00-07 FOR SPECIAL FREIGHTER. REPAIR 3 RECURRENT INSP REQUIRED IAW SRM 53-00-07, FLAG NOTE "D", 10,000 FLT CYCLES AND HFEC INSP EVERY 12,000 FLT. CYCLES INTERVAL. (CATEGORY "B"). MAJOR REPAIR.