What was found
MAIN DECK - DURING HFEC INSP, LONGERON 3, RT SPLICE FITTING AT STA 6-100, FOUND 02 EACH CRACKED APPROX 0.5 INCH. CRACKED SPLICE FITTING AT STA 6-100. R & R IAW SRM 51-31-01, REV 45. NEW LONGERON SPLICE FITTING FABRICATED IAW DOUG DWG A6A7112 REV A. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 111.