What was found
MAIN DECK STA 5-0, LONGERON 1, LT FWD EDGE FOUND 1 EACH CRACKED, APPROX 1.25 INCH LONG DURING X-RAY INSP. REPAIRED AS PER SRM 53-00-05 FIGURE 202 REPAIR 1 REVISION 45. THIS REPAIR IS CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REVISION 111.