What was found
MAIN DECK CABIN, FRAME AT STA 1561, LONGERON 12 RT FOUND DENTED. CARRIED OUT REPAIR IAW SRM 53-00-07, FIGURE 201, REPAIR 2, REV 45. REPETIVE INSP REQUIRED, INITIAL AT 14,500 CYCLES AND REPETIVE INSP AT 9,500 CYCLES TO BE CARRIED OUT IAW SRM 53-00-07, FIG 201, REPAIR 2 REV 45. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 111.