What was found
MAIN DECK - OVERWING TANK UPPER SURFACE AT STATION 1227, X= 60.5 FOUND CORROED. CORROSION REMOVED IAW SRM 51-21-01, REV 45. ORIGINAL MATERIAL THICKNESS = 0.167 INCH, REMAINING THICKNESS = 0.137 INCH. MATERIAL REMOVED = 0.030 INCH AND FOUND. ACCEPTABLE IAW EA NR1-5710-143826, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 111.