What was found
DURING NR 2 ENGINE PYLON MOUNT AFT HOLE CORROSION REMOVAL FOUND LOWER MATING FACE WITH CORROSION NEAR TO THE HOLE. REPAIRED IAW EA 6-5450-143832. DEEPEST REWORKED SURFACE: 0.019" AND MAXIMUM ALLOWABLE DEPTH: 0.0138" IAW SRM 54-51-81 CONFIGURATION 2, FIG 104, REV 19. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 111.