What was found
AFT PIT, FRAME AT BS 970 IS DENTED BETWEEN STR 25L-STR 27L. CUT OUT DAMAGED AREA IAW SRM REV 103, 51-10-1. FABRICATED DOUBLER IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 5. INSTALLED REPAIR DOUBLER IAW SRM 51-30-2 AND 51-40-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, FRAME AT BS 970 IS DENTED BETWEEN STR 25L-STR 27L. CUT OUT DAMAGED AREA IAW SRM REV 103, 51-10-1. FABRICATED DOUBLER IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 5. INSTALLED REPAIR DOUBLER IAW SRM 51-30-2 AND 51-40-3 FIG 1.