What was found
AFT CARGO COMPARTMENT DOOR CUTOUT CEILING STRUCTURE SEAL PLATE IS CRACKED BETWEEN FRAME 60 AND FRAME 61. TRIMMED OUT DAMAGED AREA IAW SRM 51-71-40, PG 202. FABRICATED REPAIR DOUBLER AND FILLER IAW SRM 51-71-40. DRILLED IAW SRM 51-40-44. ALODINED FILLER AND DOUBLER IAW SRM 51-21-10. PRIMED AND TOP COATED IAW SRM 51-23-10, PG 1. INSTALLED IAW SRM 51-40-21, PARA 6.