What was found
MAIN CARGO COMPARTMENT FLOORBEAM HAS CRACK AT FRAME 64 BETWEEN SEAT TRACK R-4 AND R-5 ( -Y1456 AND -Y1858) .5 IN LONG CUT OUT DAMAGED AREA IAW SRM 53-10-15, FIG 211, PG 389. TRIMMED FLOORBEAM IAW 53-10-15, PG 391-392. NDT CHECK FOR CRACKS IAW IAW NTM 51-10-08 NO CRACKS SHOW. FABRICATED 1 EA ANGLE IAW SRM 53-10-15, PG391-392. ALODINE, PRIMER, TOP COAT, INSTALLED REPAIR ANGLE IAW SRM 53-10-15, PART B.