What was found
REWORK OF SNRM N00090, REPAIR INSTALLED IAW INCORRECT SRM REPAIR REQUIRES REPLACEMENT. RT FUSELAGE EXT SKIN DENT AT STA 310 AND STR S23R. REMOVED EXT REPAIR AT STA 310 AND S23R IAW SRM 51-40-02, ACOMPLISHED REPAIR IAW SRM B757-200 SF 53-00-01. REPAIR 15, FIG 201 INSPECTION THRESHOLD REPETATIVE. INSP REQUIRED BEFORE 29,000 F/C REPEAT INSP LFEC INTERVAL 3000 F/C CATEGORY B REPAIR. MAJOR REPAIR.