What was found
EXISTING REPAIR FOUND AT FRAME 36 STR 32 - 33 LT EXISTING REPAIR ON FUSELAGE EXTERIOR SKIN AT FR 36 BETWEEN STRINGER 32-33 LT EVALUATED AND FOUND NOT IAW APPROVED DATA. NEW REPAIR AT FUSELAGE SKIN AT FR 36, STR 32-33, LT ACCOMPLISHED IAW SRM 53-10-12, FIG 225, REV 74. EO 6-5100-7-5000C EOCN C2 PART 1, STRUCTURES-REPAIR REVIEW AND SUPPLEMENTAL MX REQUIREMENT (SMR) TRACKING 14CFR 121.368, 121.707 PART 43 APP A. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. RE-INSP TO BE CARRIED OUT AT 37,500 FC AND REPETITIVE INSP TO BE CARRY OUT EVERY 12,000 FC.