What was found
RT, EXTERNAL FUSELAGE AT STA 1655, BETWEEN STR 24R & 25R, HAS A DENT. DENT FOUND OUT OF LIMITS PER SRM 53-00-01, FIG.101, DETAIL 3, PG.104. CLEANED DAMAGED SKIN PER SRM 53-00-01 AT RH EXTERNAL FUSELAGE BY BS 1655, BETWEEN S24-25R. FABRICATED A REPAIR DOUBLER AND INSTALLED PER SRM 53-00-01, REPAIR NR 16, AT BS 1655, BETWEEN S24-25R. THIS IS A CAT. "B" MAJOR REPAIR WITH THE FOLLOWING TRACKING; INITIAL INSPECTION AT 37,000 FC, THEREAFTER EVERY 3,000 FC.