What was found
FWD CARGO COMPARTMENT UNDER FLOOR VERTICAL WEB IS CRACKED BETWEEN FRAME 37 & FRAME 38; LBL 56. REMOVED AND REINSTALLED PALLET LATCH AT FRAME 37, RBL 33 IAW AMM 25-52-34- 04, PARA 2B1 & 2E2. REMOVED AND REINSTALLED PDU TRAY AT FRAME 37 TO 38 RT IAW SRM 51-40-21, PARA 5. REMOVED WEB IAW SRM 51-40-21, PARA 6D. LOCATED AND DRILLED WEB PN A5377833820890 IAW SRM 51-72-10, PG 2. INSTALLED WEB IAW SRM 51-72-10, PARA 6.