What was found
NR 1 STRUT AFT FAIRING LOWER DRAIN TUBE EXIT AREA MOST AFT COVER PLATE AT PP STA 280.00 HAS CRACK ON THE FWD INBD SIDE. CRACKED COVER PLATE, R & R WITH FABRICATED PLATE IAW SRM 51-40-02, REV 102. REPAIR IS CLASSIFIED AS MINOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 STRUT AFT FAIRING LOWER DRAIN TUBE EXIT AREA MOST AFT COVER PLATE AT PP STA 280.00 HAS CRACK ON THE FWD INBD SIDE. CRACKED COVER PLATE, R & R WITH FABRICATED PLATE IAW SRM 51-40-02, REV 102. REPAIR IS CLASSIFIED AS MINOR.