What was found
FWD CARGO COMPT FLOOR DECK PLATE SUPPORT RT CHANNEL UNDER SURFACE AT STA 740 RBL 10.45 - RBL 16.10 FOUND WITH CORROSION. CORRODED CHANNEL REMOVED AND REPLACED IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO COMPT FLOOR DECK PLATE SUPPORT RT CHANNEL UNDER SURFACE AT STA 740 RBL 10.45 - RBL 16.10 FOUND WITH CORROSION. CORRODED CHANNEL REMOVED AND REPLACED IAW SRM 51-40-02 REV 101. REPAIR IS CLASSIFIED AS MINOR.