What was found
MAIN CABIN OVERWING FLOORBEAM TEE CRACKED AT RADIUS BS 760.9 LBL45. REMOVED FLOORBEAM SECTION AT LBL45, BS 760.9 IAW SRM REV 103, 51-30-2. FABRICATED FLOORBEAM SECTION TEE IAW DWG 65-16279 & INSTALLED IAW SRM 51-30-2 AND DWG 65-16279.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN OVERWING FLOORBEAM TEE CRACKED AT RADIUS BS 760.9 LBL45. REMOVED FLOORBEAM SECTION AT LBL45, BS 760.9 IAW SRM REV 103, 51-30-2. FABRICATED FLOORBEAM SECTION TEE IAW DWG 65-16279 & INSTALLED IAW SRM 51-30-2 AND DWG 65-16279.