What was found
MAIN CABIN OVEERWING FLOORBEAM TEE CRACKED AT RADIUS BS 760.9 LBL 24. REMOVED DAMAGED TEE, FABRICATED NEW TEE AND INSTALLED IAW DWG 65-16279, SRM 51-10-1, 51-10-2, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN OVEERWING FLOORBEAM TEE CRACKED AT RADIUS BS 760.9 LBL 24. REMOVED DAMAGED TEE, FABRICATED NEW TEE AND INSTALLED IAW DWG 65-16279, SRM 51-10-1, 51-10-2, AND 51-30-2.