What was found
RT WING L/E COMP AT STA XORS 510 FOUND FINGER DOUBLER WITH APPROX (5) INCH CRACK L/E SKIN ARB7574-2, XOS 620. TRIMMED IAW SRM 57-40-02, REPAIR 9, FIG 203, REV 46. HFEC C/OUT ON REPAIR AREA FOUND NO CRACK EVIDENT. FABRICATED DOUBLER, ANGLE AND FILLER; AND INSTALLED IAW SRM 57-40-02, REPAIR 9, FIG 203, REV 46. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.