What was found
PREVIOUS DENT OBSERVED ON RH FUSE SKIN 15 INCH AFT FR77 17 INCH BELOW STR 24. REPAIR CARRIED OUT IAW SRM 53-10-12 REPAIR DOUBLER INSTALLED IAW SRM 53-10-10 FIG 225 ORIGINAL SKIN THICKNESS 0.063" REPAIR DOUBLER 0.071" THICK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PREVIOUS DENT OBSERVED ON RH FUSE SKIN 15 INCH AFT FR77 17 INCH BELOW STR 24. REPAIR CARRIED OUT IAW SRM 53-10-12 REPAIR DOUBLER INSTALLED IAW SRM 53-10-10 FIG 225 ORIGINAL SKIN THICKNESS 0.063" REPAIR DOUBLER 0.071" THICK.