What was found
MAIN CABIN STA 365, BL-0 FLOORBEAM CORRODED UPPER FLANGE. REMOVED CORROSION IAW SRM 51-10-02. ORIGINAL MATERIAL .125 AFTER REWORK .098. EXCEEDED MAX ALLOWABLE DAMAGE REMOVAL OF .107 IAW SRM 53-00-51 FIG 101 DETAIL III. AREA OUT OF LIMITS. REMOVED DAMAGED AREA OF BEAM REPAIR IAW SRM 51-40-02. FABRICATED NEW TEE, REPAIR ANGLES AND REPAIR STRAPS IAW SRM 51-40-02 AND SRM 53-00- 51 TABLE 1. INSTALLED REPAIR CHORD, ANGLES AND STRAPS IAW SRM 51-40-02. CLASSIFED CATEGORY "A" MAJOR REPAIR