What was found
RT WING RIB 5 FITTING HAS 2 EA SECOND OVERSIZE LOCK FASTENER INSTALLED IN HOLES 47/54. REAMED AND COUNTERSUNK HOLES 47 AND 54 TO THIRD OVERSIZE INTERFERENCE FIT 0.8095 IAW EA 6-5710-136750 AND REPAIR DWG R57150117 ISSUE B INSTALLED OVERSIZE FASTENERS IAW SRM 51-40-21, PARA 7 AND TORQUED IAW SRM 51-40-00, TABLE 9. TITLE: WINGS AD 2010-23-26-EO6-5710-7-3325, SBA300-57-6110. MLG RIB 5 SPOTFACE ON THE BOTTOM FLANGE.