What was found
CORROSION WINDOW FRAME RT SIDE STA. 950 REMOVED CORROSION IAW SRM 51-10-6. MEASURED BLEND TO BE OUT OF LIMITS IAW SRM 56-20-1 FIG 1. FABRICATED DOUBLER REPAIR AND INSTALLED DOUBLE REPAIR IAW SRM 56-20-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WINDOW FRAME RT SIDE STA. 950 REMOVED CORROSION IAW SRM 51-10-6. MEASURED BLEND TO BE OUT OF LIMITS IAW SRM 56-20-1 FIG 1. FABRICATED DOUBLER REPAIR AND INSTALLED DOUBLE REPAIR IAW SRM 56-20-3 FIG 1.