What was found
RT WING L/E DROOP SLAT UPPER SKIN FOUND WITH APPROX 1.75 INCH CRACKED. STOP DRILLED IAW SRM 57-40-01 REV 46, REPAIR 5, FIG 201. REPAIR DOUBLER FABRICATED IAW SRM 57-40-01, REV 46, REPAIR 5, FIG 201 AND INSTALLED IAW SRM 51-33-01, REV 46. REPAIR AREA REPROTECTED IAW SRM 51-21-01, REV 46. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.