What was found
05 EA FASTENER HOLES FOUND CRACK INDICATION DURING HFEC OPEN HOLE INSP AT RT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STATION XORS=683.4 AND STATION XORS=713.6. CARRIED OUT REPAIR AS PER DRAWING SG11570004 REVISION B. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100 REVISION 112.