What was found
DENTS 2EA EXTERIOR FUSELAGE STA 1050 BETWEEN STR 16R-17R. CUT OUT DAMAGED AREA IAW SRM 51-10-1. FABRICATED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 3 AND INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 3 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENTS 2EA EXTERIOR FUSELAGE STA 1050 BETWEEN STR 16R-17R. CUT OUT DAMAGED AREA IAW SRM 51-10-1. FABRICATED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 3 AND INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 53-30-3 FIG 3 AND 51-30-2.