As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER FRAME REMOVAL AND CLEAN UP FOUND DOUBLE DRILL HOLES STA 620 BETWEEN STR 10L TO STR 13L. CUTOUT DAMAGED AREAS (3) AT BS 620 STR 10L, STR 11L, AND STR 13L AND FABRICATED FILLERS (3). INSTALLED FILLERS (3) AND FABRICATED REPAIR DOUBLER AND REPAIR TRIPLER. INSTALLED REPAIR DOUBLER AND REPAIR TRIPLER AT BS 620 IAW B727 SRM 51-30- 2, FEDEX EA 7-5310-123595, SRM 51-10-2 AND EA 7-5310-123595.