What was found
LT WING OTBD FLAP NR 2 SECONDARY UP STOP BOLT FITTING FOUND CRACKED. DAMAGED FITTING REMOVED IAW SRM 51-31-01, REV 46 AND INSTALLED NEW FITTING IAW DWG ARC 4125, REV G. THIS REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT WING OTBD FLAP NR 2 SECONDARY UP STOP BOLT FITTING FOUND CRACKED. DAMAGED FITTING REMOVED IAW SRM 51-31-01, REV 46 AND INSTALLED NEW FITTING IAW DWG ARC 4125, REV G. THIS REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 112.