What was found
5" SQUARE OF EXFOLIATION COROSSION ON MDC SEAT TRACK 3L INBD FLANGE, 6" FWD OF FR19 TO 11" FWD OF FR19. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK 3L FR 15 TO FR 19 IAW SRM 51-72-10 PG 1-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
5" SQUARE OF EXFOLIATION COROSSION ON MDC SEAT TRACK 3L INBD FLANGE, 6" FWD OF FR19 TO 11" FWD OF FR19. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED SEAT TRACK 3L FR 15 TO FR 19 IAW SRM 51-72-10 PG 1-3.