What was found
1EA DISBONDED AREA (2.5" X 1.8") WAS FOUND AT 322BL PANEL L/H SIDE. (6" FROM LEADING EDGE, 27" FROM BOTTOM EDGE.) CLEANED & EVALUATED THE DIMENSION OF THE DISBONDED AREA 9" X 8.5". REINFORCED REPAIR THE AREA WITH THE RESIN COMPOUND AND FIBERGLASS CLOTH REFER TO A310 SRM 55-32-00.