What was found
LOWER FUSE NLG RT TRUNNION FITTING FOUND CRACKED. HFEC INSP CARRIED OUT ON CRACKED AREA FOUND CRACK APPROX 1" IN LENGTH. TRIMMED OFF IAW SRM 53-10-14, FIG 201. REPAIR NR 2 REV 46. HFEC INSP CARRIED OUT ON TRIMMED AREA FOUND NO CRACK. REPAIR DOUBLER & FILLER FABRICATED IAW SRM 53-10-14, FIG 201. REPAIR CLASSIFIED AS MAJOR IAW GMM6-2-100, REV 112.