What was found
LEFT WING OTBD FLAP, OTBD HINGE (WING SIDE) UPPER OTBD MOUNT HOLE FOUND CORRODED. REWORKED IAW EA 1-5740-147654, PART 1(B). EXISTING HOLE: 0.881", FINAL HOLE: 0.947", MAX.HOLE: 0.944". NEW BUSHING FABRICATED AND INSTALLED IAW EA 1-5740-147654, PART 1(B). REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.