What was found
LEFT WING OTBD FLAP, OTBD HINGE (WING SIDE) SIDE LINK HOLE SPOT FACE, FOUND CORRODED. REWORKED IAW CMM 20-11-02 REV 70. REMOVED: 0.003", FOUND THE REMAINING THICKNESS OF 0.460" AND 0.464" IS WITHIN DWG ARC 503 SHEET 2 BG LIMITS AND CMM 57-44-09 REV 70 FIG.601 AND 601 IN SERVICE REWORK LIMIT. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100 REV 112.