What was found
DURING X-RAY INSP, CRACK FOUND AT STA 5-0, STR 11L ON FWD INBD ROW NR3 TO NR4 FASTENER TO EDGE OF STRINGER AS MARKED. REPAIRED AS PER SRM 53-00-05 FIG 202 REPAIR 1 REV 46. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING X-RAY INSP, CRACK FOUND AT STA 5-0, STR 11L ON FWD INBD ROW NR3 TO NR4 FASTENER TO EDGE OF STRINGER AS MARKED. REPAIRED AS PER SRM 53-00-05 FIG 202 REPAIR 1 REV 46. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 112.