What was found
FLOORBEAM AT BS 680, LBL 45 TO RBL 25 HAS CORROSION. REMOVED CORROSION, CUTOUT DAMAGED AREA IAW SRM 51-10-6, FABRICATED REPAIR PARTS IAW SRM 53-10-8, INSTALLED REPAIR PARTS IAW SRM 51-30-5, 51-10-2, 51-30- 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT BS 680, LBL 45 TO RBL 25 HAS CORROSION. REMOVED CORROSION, CUTOUT DAMAGED AREA IAW SRM 51-10-6, FABRICATED REPAIR PARTS IAW SRM 53-10-8, INSTALLED REPAIR PARTS IAW SRM 51-30-5, 51-10-2, 51-30- 2.