What was found
FLOORBEAM CORRODED STA 620 BL 0 TO LBL 24. CUTOUT DAMAGED AREA IAW SRM 51-10-2. FABRICATED REPAIR PARTS IAW SRM 53-10-8 FIG 3. TREATED AND PRIMED NEW PARTS IAW SRM 51-10-2. INSTALLED NEW PARTS IAW SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CORRODED STA 620 BL 0 TO LBL 24. CUTOUT DAMAGED AREA IAW SRM 51-10-2. FABRICATED REPAIR PARTS IAW SRM 53-10-8 FIG 3. TREATED AND PRIMED NEW PARTS IAW SRM 51-10-2. INSTALLED NEW PARTS IAW SRM 51-30-2.